General Information General Information The Marson PHT-3 pneumatic/ hydraulic riveting tool is designed to set all-steel KLIK rivets and their equivalents in sizes from 1/8" to 3/16" diameter. Model PHT-3 is supplied with 3/16" nosepiece (1) installed in the operating position. Standard nosepieces for 5/32" (1A) and 1/8" (1B) diameter rivets is included among the accessories supplied with the tool. The Maximum Air Pressure is 100 PSI At Tool. Specifications Rivet Setting Capacity 3/16" diameter Traction power 1983 lbs Operating air pressure 90 PSI Air consumption .04 Cu. Ft./stroke Air Inlet 1/4" N.P.T. Overall height 12 ¾" Net weight 3.3 lbs. Accessories The PHT-3 is packaged in a compartmented storage container. Wrenches needed to service the tool are included. Special WRENCH (40) has a cut-out gauge used in adjusting the tool as described below. Also included: PLASTIC BOTTLE (48) to catch ejected mandrels when attached to the back of the tool. Maintenance In order to achieve maximum efficiency and economy, the Marson PHT-3 pneumatic/hydraulic riveting tool should be serviced and maintained on a regular basis. No special skills or tools other than the ones provided are needed to properly service and maintain the device. The operative parts of the tools requiring regular inspection and maintenance are as follows:
Maintenance Procedures 1. Cleaning and Changing Jaws IMPORTANT – Disconnect the PHT-3 from the air pressure line before proceeding with inspection or repairs. Use WRENCH (40) to remove HEAD (2) and JAW HOUSING (3). At the same time, hold the JAW HOUSING COUPLER (8) with an open-end wrench. Clean jaws with solvent or a steel brush. Replace with new jaws if excess wear is apparent. Always coat outer or smooth surface of jaws with an oil film before assembling. Reassemble by reversing order of above procedure. It is important that JAW PUSHER (5) engages the conical parts of the jaws. DO NOT CHANGE THE POSITION OF PARTS (7) and (8). If these parts are inadvertently changed, see readjustment instructions under "Malfunction."
Connect PHT-3 to air pressure and press TRIGGER ARM (30) until nosepiece has been removed and new nosepiece fully tightened. When TRIGGER ARM (30) has been released and tool is at rest there should be a circular opening visible in the nosepiece. Malfunction
CAUSE: Insufficient oil. REPAIR: See repair instructions under Malfunction, 1. CAUSE: Not enough air pressure. REPAIR: Increase air pressure but do not exceed 100 PSI at tool. CAUSE: Loose nosepiece. REPAIR: Tighten nosepiece with WRENCH (40). CAUSE: JAW HOUSING COUPLER (8) too far forward. REPAIR: See procedure under Section 2 above.
44 Campanelli Pkwy. Stoughton, MA. 02072 Tel. (800) 344-9664 Fax (800) 644-2177
|